See what a Modern Building
inspection report looks like.

Below is a real (anonymized) inspection report from a South Florida 3-bed/2-bath built in 2006 — performed by Jorge in February 2026. Buyer info has been redacted; everything else (37 deficiencies, severity ratings, photos, repair estimates) is exactly what you'll receive within 24 hours of your inspection.

Book this inspection Download PDF copy
Modern Building Inspections Interactive digital report
Property inspection report

[Sample property]
South Florida

Inspected: Feb 24, 2026
Inspector: Jorge Garcia, FL HI#13420
Built: 2006 · Sqft: 1,749 · Beds: 3 / 2
Client: [Anonymized buyer]
Sample property front elevation illustration
3
Critical / Safety
12
Major defect
22
Minor / Repair
14
Informational
18
Maintenance
All findings Critical Major Roof Electrical Plumbing
Photos: 187 Pages: 54
Critical
Electrical · Main panel

Federal Pacific Stab-Lok panel — recalled product, fire hazard

The main service panel is a Federal Pacific Stab-Lok model. These panels have a documented failure rate of approximately 60% to trip during overload, posing a substantial fire risk. Recommend a licensed electrician replace the panel before move-in.
Federal Pacific Stab-Lok electrical panel illustration with hazard callout
💰 Estimated repair cost: $2,800 – $4,200
Critical
Plumbing · Water heater

Water heater missing TPR discharge tube

The temperature/pressure relief valve has no discharge piping. Per Florida Building Code 504.6, this creates a scalding and rupture risk. Discharge must terminate within 6" of the floor with rigid copper or CPVC.
Water heater with missing TPR discharge tube illustration
💰 Estimated repair cost: $95 – $180
Major
Roof · South-east slope

3 cracked clay tiles; underlayment exposure visible from roof inspection

Roof inspection captured three cracked clay tiles along the south-east hip ridge with adjacent underlayment exposure. No active leak observed at the time of inspection, but failure mode is imminent without near-term repair.
Cracked clay tile roof illustration with annotated findings
💰 Estimated repair cost: $450 – $850
Major
HVAC · Air handler

Air handler 18 years old · refrigerant R-22 (discontinued)

The air handler is past its expected service life (12-15 years) and uses R-22 refrigerant which the EPA phased out in 2020. Repairs that require refrigerant recharging will be costly and limited in supply. Replacement should be budgeted within 1-2 years.
Outdoor AC condenser with R-22 refrigerant nameplate illustration
💰 Estimated replacement: $5,200 – $7,800
Minor
Exterior · West-side wall

Hairline stucco crack — non-structural

Vertical hairline stucco crack at the west elevation near the kitchen window, approximately 4 feet long. Consistent with normal settlement; no evidence of structural movement. Recommend sealing with elastomeric caulk to prevent moisture intrusion.
Hairline stucco crack on exterior wall illustration
💰 Estimated repair cost: $50 – $120
… 60 additional findings, 187 photos, repair-request builder, and a digital signature page follow in the live report.
What makes our reports different

Built for negotiation,
not the recycle bin.

1-click repair requests

Check the items you want addressed; the report auto-generates a clean repair addendum your agent can send the same day.

Severity-rated findings

Every defect gets a 1-5 severity tag (Critical, Major, Minor, Info, Maintenance). Your attorney instantly knows what's negotiable.

Photos & video documentation

Thermal scans, high-res close-ups, and video walk-throughs of every concern flagged. If we mention it, you see it. Searchable by room or system.